Instruction: Voltage Adjustment: Power on module while not connect to load, then adjust "V-ADJ" potentiometer clockwise to increase, counterclockwise to decrease.Due to large output capacitance capacity, response be slow when adjust high voltage to low voltage. Current Adjustment: Adjust "CC A-ADJ" potentiometer counterclockwise about 30 circles to minimize the output current before connecting to load.Then adjust "CC A-ADJ" clockwise to the current value you need.If you use the module for battery charging, connect to output after battery is fully discharged. Because if the more energy is left in battery, the less charging current be. Low Input Voltage Protection Adjustment: If we set a low input voltage protection for a 12V battery, connect input to a 10V voltage, then adjust RV1(clockwise to increase, counterclockwise to decrease) till UVLO light up.Now the protection voltage is 10V, that is to say, when battery voltage drops to 10V, module 't step up voltage and the output voltage